Description

This procedure describes the role of Zero-Air Generators in supplying pure, dry air as a source of calibration standard. This Standard Operating Procedure details two alternate Zero-Air sources:...


Views: 1168
Updated

February 1, 2011

Description

This procedure describes the operation and maintenance of the BIOS DC-2 flow meter. This device is used to measure air flow rate either from vacuum or pressure flow sources.


Views: 624
Updated

February 1, 2011

Description

The Puregas and Bendix model air dryers are designed to effectively remove moisture or other unwanted components from a compressed air stream. They separate the various components using Pressure...


Views: 489
Updated

January 27, 2011

Description

To obtain timely data for the purpose of air quality assessment, air quality trend reporting, air quality index reporting and to meet the requirements for inclusion of the data in provincial and...


Views: 805
Updated

January 27, 2011

Description

For the purpose of collection of ambient air samples for determination of polyaromatic hydrocarbons (PAH), Polychlorinated biphenols (PCB’s), dioxins and furans, and pesticides a high volume...


Views: 355
Updated

January 24, 2011

Description

To obtain timely data for the purpose of air quality assessment, air quality trend reporting, air quality index reporting and to meet the requirements for inclusion of the data in provincial and...


Views: 290
Updated

January 24, 2011

Description

This SOP is intended to provide instruction on operation of the Mobile Air Monitoring Laboratory as it relates to air quality monitoring operations and the data generated during those operations.


Views: 485
Updated

January 24, 2011

Description

This procedure describes the operation and maintenance of the Vaisala PTB 220 digital barometer. This sensor can be used for handheld measurements, and can be connected to a computer via RS232...


Views: 462
Updated

January 24, 2011

Description

Daily data of instrument baseline and upscale response is required to verify instrument performance. The R & R Model 200 provides a stable span source. To meet the requirements for inclusion...


Views: 272
Updated

January 24, 2011

Description

To obtain timely data for the purpose of air quality assessment, air quality trend reporting and to meet the requirements for inclusion of the data in provincial and national air quality...